RILEM TUBES

For measuring the rate at which water moves
through porous materials such as masonry

See how it works!

Rilem Tubes (used in the Rilem Test Method) provide a simple method for measuring the volume of water absorbed by a masonry material within a specified time period. The test can be performed at the site or in the laboratory and can be used to measure vertical or horizontal water transport. Water permeability measurements can be used to assess the degree of weathering that the material has undergone. This testing can also determine the degree of protection afforded by a water repellent treatment.


Vertical Rilem Tubes — Regular

Used to measure absorption of a vertical masonry surface.

 

Check price list


Horizontal Rilem Tubes

Used to measure absorption of a horizontal surface.

 

Check price list


Rilem Putty
Rilem Putty is used to attach the Rilem Tube to the surface being tested. Each unit of Rilem Putty contains 1/2 pound of putty. Approximately twelve rilem tubes can be attached with 1/2 pound of putty.

Rilem Putty

Check price list


Read about the Rilem Test Method